ABS Material 245*225mm Panel Size Audio Visual Sockets Junction Box

Short Description:

 


  • Port: Wenjiang
  • Technical Parameters

    Features

    LVD test report

    Application

    Product Tags

    Quick Details:

    Serial No. Parameter Description

    1

    Safewire item

    HTD-624AS-120

    2

    Material

    ABS, galvanised steel

    3

    Overall Frame & Lid (mm)

    245*225

    4

    Compact floor cut-out(mm)

    (210-215)*(230-235)*(76-110)

    5

    Thickness of concavity/Frame lid recess (mm)

    8

    6

    Installation depth(mm)

    76~110

    7

    Plug top clearance(mm)

    13~48

    8

    Available modules

    2WAYS 128TYPE modules

    9

    Accessories plates

    90*80mm

     

    Application:

    Feature of Safewire floorbox:

    Attentions:

    1.Dispose of trash in bottom box and prevent dirt and debris from entering inside.

    2.The sealing ring is closely attached to the smooth surface to prevent water leakage.

    3.When installing, pay attention to the opening direction,the length of the conductor to the bottom box shall not exceed 10cm,Set aside at least 200mm of cable.

    4.When installing and wiring,Product should avoid direct contact with corrosive liquid, gas (strong acid, strong alkali, paint).

    5.Please close cover when not used.

     

    Safety Warning

    1.This is a class I product and must be earthed

    2.This product must be installed/wired by a qualified electrician

    3.For indoor use only.

    4.For concrete floor/access floor.base on different bottom box.

    1.Floor box(For concrete floor)

    Align floor box in centre as delivered.Bend open ears and fix to raw ceiling.

    2.Steel armored conduit(For trunking system/Access floor).Bend open perforation in the sides of floor box and insert steel armored conduct.

    3.Put under floor box into cut out and adjust height(For raised floor) .Put under floor box into hole/location of raised floor.Then move the adjustable screw in clockwise direction until screws are tightened with flooring.lead the lines into plastic bottom box.

    4.Installing Heavy current/Data systems

    Insert heavy current devices from the top and connect from below and snaptabs into the frame;Insert connected data Jacks from below into the plate,Fasten equipped plate accordingly.

    5.Connecting and earthing.

    Connect heavy current/Data with the lines which are lead into bottom box.And connect earthing lines of floor cable systems with earthing screw of bottom box torgue0.4N.m.Verify reliable and safe.

    6.Assembly and plug into underfloor box.

    Inset heavy current and low current plugs into frame.

    7.Single outlet

    Lead heavy and low current plug cable cord from edge lord outlet lid.

    Filling stuff and levelling to floor

    Fill the sunken area of panel neatly with filling stuff according surface material of floor .Adjust wnder floor box height flush over the four levelling screws.

     

     

    Attentions:

    1.Dispose of trash in bottom box and prevent dirt and debris from entering inside.

    2.The sealing ring is closely attached to the smooth surface to prevent water leakage.

    3.When installing, pay attention to the opening direction,the length of the conductor to the bottom box shall not exceed 10cm,Set aside at least 200mm of cable.

    4.When installing and wiring,Product should avoid direct contact with corrosive liquid, gas (strong acid, strong alkali, paint).

    5.Please close cover when not used.

     

    Safety Warning

    1.This is a class I product and must be earthed

    2.This product must be installed/wired by a qualified electrician

    3.For indoor use only.

    4.For concrete floor/access floor.base on different bottom box.

     


  • Previous:
  • Next:

  • 1Our floor boxes are boxes for installation recessed in floor with possibilities of add decorative materials like carpet, parquet or other finishes, on the lid.The lid made of ABS material as per RoHS certification, resistant to high temperature and corrosion.

    2capacityHTD-626AS can install 8 ways (45*45mm Legrand’s Mosaic modules)

    3Thicknes of concavity/Frame lid recess be 8mm;

    4The height of the bottom box reaches 95mm,There is enough space inside the bottom box to install the cable

    5The static pressure force over 1000 N.

    Available sockets or modules types: