One of Hottest for Dual Usb 2 Outlet Socket - RCD0230SMG – Safewire Electric Detail:
| Serial No. | Parameter | Description |
|
1 |
Model Number |
RCD0230SMG(Double RCD metal socket,switched) |
|
2 |
type |
double pole,13A RCD |
|
3 |
Rated Voltage |
240V |
|
4 |
Rated Current |
13Amax |
|
5 |
Tripping current | 10mA & 30mA |
|
6 |
Rated trip current | 30mA |
|
7 |
Trip speed |
less than 40ms |
|
8 |
Cable capacity |
3*2.5mm2 |
|
9 |
Standard |
CE BS7288 BS1363 |
|
10 |
Remarks |
Fuse inside |
|
11 |
Application |
Residential / General-Purpose |
|
12 |
color |
white |
|
13 |
material |
metal |
|
14 |
Size |
146*86mm |
|
15 |
Minimum back box depth |
37 |
|
16 |
Useful | home appliances, portable equipments, garden tools, construction sites |
Product detail pictures:




Related Product Guide:
Phanteks extension cables melting – Components | Australia Power Plug Socket
2019 LEVC TX Taxi Review: Driving the New Plug-In Hybrid London Taxi | Extension Sockets
One of Hottest for Dual Usb 2 Outlet Socket - RCD0230SMG – Safewire Electric, The product will supply to all over the world, such as: , , ,
The enclosures of all maintenance boxes shall be fabricated from halogen-free, non-toxic, and environmentally sustainable materials. Their corrosion resistance shall be capable of withstanding exposure to solutions with an acid concentration of 10% or an alkali concentration of 10% and above. The material shall exhibit a temperature stability range of no less than -40°C to +90°C, and its flame resistance temperature in the hot filament test shall not be lower than +960°C. It shall possess properties such as full insulation, dust resistance, water resistance, corrosion resistance, impact resistance, UV resistance, heat resistance, flame retardancy, shock resistance, and high mechanical strength.
Sectional maintenance boxes shall be made of polycarbonate material, which is characterized by corrosion resistance, halogen-free composition, flame retardancy, and self-extinguishing capability. The impact resistance rating shall meet IK09, and the box body shall be of an integrated design. Sealing bolts shall be provided for cable entry into the maintenance boxes, and sufficient space for incoming cables shall be considered. Sockets shall have high impact resistance and corrosion resistance; industrial connectors shall have a protection rating of IP67. Sockets and circuit breakers shall be mounted on the surface of the box body for ease of operation, with specific configurations detailed in the system diagram of the sectional maintenance boxes. The overall protection rating of the maintenance boxes shall reach IP66.