Safewire HTD-626AS-120 TUV CE certificated access floor boxes cavity floor boxes EV charging station

Short Description:

Serial No. Parameter Description

1

Safewire item

HTD-626AS/SS/SP-120

2

Material

ABS, galvanised steel

3

Overall Frame & Lid (mm)

320.5*230.5

4

Compact floor cut-out(mm)

(305-310)*(210-215)*(76-110)

5

Thickness of concavity/Frame lid recess (mm)

8

6

Installation depth(mm)

76~110

7

Plug top clearance(mm)

13~48

8

Available modules

128TYPE modules

9

Accessories plates

90*80mm

10

Bearing capacity

1000 N

 

installation package

 

 

Safety Warning

1.This is a class I product and must be earthed

2.This product must be installed/wired by a qualified electrician

3.For indoor use only.

4.For concrete floor/access floor.base on different bottom box.

 


  • Port: Wenjiang
  • 4 gangs GFCI outlet: 4 gang data
  • Raised floorbox: with adjustable floorbox
  • Technical Parameters

    Materials and protection requirements for distribution box products

    Product Tags









  • Previous:
  • Next:

  • The enclosures of all maintenance boxes shall be fabricated from halogen-free, non-toxic, and environmentally sustainable materials. Their corrosion resistance shall be capable of withstanding exposure to solutions with an acid concentration of 10% or an alkali concentration of 10% and above. The material shall exhibit a temperature stability range of no less than -40°C to +90°C, and its flame resistance temperature in the hot filament test shall not be lower than +960°C. It shall possess properties such as full insulation, dust resistance, water resistance, corrosion resistance, impact resistance, UV resistance, heat resistance, flame retardancy, shock resistance, and high mechanical strength.

    Sectional maintenance boxes shall be made of polycarbonate material, which is characterized by corrosion resistance, halogen-free composition, flame retardancy, and self-extinguishing capability. The impact resistance rating shall meet IK09, and the box body shall be of an integrated design. Sealing bolts shall be provided for cable entry into the maintenance boxes, and sufficient space for incoming cables shall be considered. Sockets shall have high impact resistance and corrosion resistance; industrial connectors shall have a protection rating of IP67. Sockets and circuit breakers shall be mounted on the surface of the box body for ease of operation, with specific configurations detailed in the system diagram of the sectional maintenance boxes. The overall protection rating of the maintenance boxes shall reach IP66.