Twin RCD Plastic Socket, Unswitched

Short Description:

 


  • Port: Wenjiang
  • Technical Parameters

    Product Tags

    Specification 

     

    Serial No. Parameter Description

    1

    Rated Voltage

    240V

    2

    Rated Current

    13A

    3

    Tripping current 10mA & 30mA

    4

    Rated trip current  30mA

    5

    Trip speed

    less than 40ms

    6

    Cable capacity

    3*2.5mm2

    7

    Standard

    AS NZS3190 & NZS3112 SAA

    8

     Remarks

    Fuse inside

    9

    Application

    Residential / General-Purpose

    10

    color

    white

    11

    material

    PC

    12

    Size

    118*75*45mm

    13

    Endurance

    2000 Cycles min

    14

    Hit-Pot Test

    2000V/1 Minute

    15

    Application

    Equipment, Household appliances, workshop and outdoors,etc.

    16

    Voltage Surge

    6 KV(100K Hz Ring Wave)

     

    Product Show:

    RCD0230SPWA

    Features

    1.Non-Latching RCD (Sometimes called Active) – When the power is lost due to earth fault or power cut, the RCD isolates the circuit that it is protecting and remains off until it is manually reset. A must for protecting circuits supplying rotating machinery or some heating apparatus for example.

     

    1. BS standard switch/unswitched socket:

    BS standard socket outlet for protect the appliance user against earth faults evev in the situation where the Live and Neutral have been reversed.

    1. Tripping current is 30mA:

    Ideal for anywhere where personal protection is required when using electrical appliances and equipment,minimizing the risks of fatal electric shocks to people. Perfect in the household environment, especially in the kitchen, bathroom, and other high usage areas.

     

    Product Application:

    Applicable to Low-voltage equipment,home appliance and Safewires floor box enclosure.

     

    Principle of RCD Operation

    An RCD protects by constantly monitoring the current flowing in the live and neutral wires suppling a circuit or an individual item of equipment. Under normal circumstances, the current flowing in the two wires is equal. When an earth leakage ocours due to a fault in the circuit or an accident with the equipment, an imbalance occurs and this is detected by the

    RCD, which aumtoatically cuts off the power before injury or damage can result.

     

    Warranty:

    12 months after date of B/L from Safewire Electrical Co.Ltd.

    Safety Warning

     

    Disconnect the rcd unit prior to insulation test.

     